ELECTRIC PANEL FOR PNEUMATIC PUMPS

The electric panel allows the pneumatic system to carry out the ON/OFF cycles of comrpessed air.

The electric panel for pneumatic pumps can be combined to various pneumatic systems: pneumatic pump total fluid top inlet 2”pneumatic pump total fluid top inlet 3”pneumatic pump total fluid bottom inlet 2”active skimmer.The electric panel allows the pneumatic system to carry out the ON/OFF cycles of compressed air, fundamental for its proper functioning. The electric panels for pneumatic pumps (IP55) are charged by 230V alternating energy and they can be arranged for one or more command lines. Each line is regulated by a solenoid valve and an ON/OFF regulating timer. It is possible to connect up to four pneumatic pumps to a single line; in that case, each pump would have the same regulation of the ON/OFF times. Hydrogea predisposes all panels with a Tank Full contact that closes the solenoid valve/s in case, for example, of the filling of a storage tank. The regulation of the ON/OFF times, that open or close the 230V solenoid valve, positioned outside the panel, is implemented by a double ON/OFF rotary selector. The compressed air that feeds the pneumatic pump is connected at the entry of the solenoid valve, whose exit is connected to the entry of the pneumatic pump. The cyclic and repeated action of opening (ON) and closing (OFF) of the solenoid valve allows the pump to function. The regulation of the ON/OFF times depends on the flow desired. Hydrogea normally suggests ON times sufficiently short to empty the pneumatic pump.

fewfw

Product page

poster_2_up

PNEUMATIC PANEL FOR PNEUMATIC PUMPS

The pneumatic panel for pneumatic pumps allows the pneumatic system to carry out the ON/OFF cycle of compressed air.

The pneumatic panel for pneumatic pumps can be combined to various pneumatic systems:pneumatic pump total fluid top inlet 2” pneumatic pump total fluid top inlet 3” pneumatic pump total fluid bottom inlet 2”active skimmer.The pneumatic panel allows the pneumatic system to carry out the ON/OFF cycles of compressed air, fundamental for its proper functioning. The pneumatic panels for pneumatic pumps work thanks to the same compressed air that allows the functioning of the pneumatic pump/s connected to it. The electric power is not needed. The regulation of the ON/OFF cycles is accomplished by two rotary selectors situated inside the panel. The ON selector should be activated for a period of time that goes from 0 to 30 seconds (depending on the inlet pressure that should be between 2 and 5 bars), the same is valid for the OFF selector (0 to 30 seconds). It is possible to connect up to four pneumatic pumps to each pneumatic panel, in that case all pumps would have the same regulation of ON/OFF times. It is possible to increase up to 30 minutes the OFF times by adding a lung. There is a floating pneumatic valve (pneumatic level switch) that allows to close mechanically the pneumatic feeding circuit of the pneumatic panel in case, for example, of the filling of a storage tank.

  • Dimensions: 32 x 24 x 13

  • Minimum pressure: 2.5 bar

  • ON regulation: 30"

  • OFF regulation: 30" (It is possible to increase up to 30 minutes the OFF times by adding a lung.)

Product page

poster_2_up

PNEUMATIC PUMP TOTAL FLUID TOP INLET 2"

Pneumatic submersible pump top inlet 2”.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven.This pump is used for the extraction of water from the bottom of wells orpiezometers or liquids with lower density than water. Adjustable pulses of compressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The compressed air pulses and, therefore, the control of the pump are started by a panel, that can be electric or pneumatic as well. This panel is essential in order to allow the functioning of all The pump consists of a bronze head, a bronze pad,a connection for the entry of compressed air, a non-return valve for the flowof liquids, a ball non-return valve for the top loading. 

  • External diameter: 48,3 mm

  • Max flow rate: 10 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 m

Product page

poster_2_up

PNEUMATIC PUMP TOTAL FLUID TOP INLET 3"

Pneumatic submersible pump top inlet 3”.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven. This pump is used for the extraction of water from the bottom of wells or piezometers or liquids with density lower than water. Adjustable pulses of compressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The pump consists of a bronze head, a bronze pad, a connection for the entry of compressed air, a non-return valve for the flow of liquids, a ball non-return valve for the top loading.  

  • External diameter: 76 mm

  • Max flow rate: 10 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 mt

Product page

poster_2_up

PNEUMATIC PUMP BOTTOM INLET 2"

Pneumatic submersible pump total fluid bottom inlet.

The pneumatic pump total fluid is a submersible pump that is pneumatically driven.This pump is used for the extraction of water from the bottom of wells orpiezometers or liquids with density higher than water. Adjustable pulses ofcompressed air assure the pump’s operation. The control/regulation of the pump can be electric or pneumatic. The pump consists of a bronze head, a bronze pad,a connection for the entry of compressed air, a non-return valve for the flowof liquids and a ball non-return valve for the bottom loading.

  • External diameter: 48,3 mm

  • Max flow rate: 20 l/min

  • Pump body: inox AISI 304

  • Inlet pressure: 0 – 8 bar

  • Max delivery height: 80 mt

Product page

poster_2_up

PNEUMATIC LEVEL SWITCH

Level switch for pumping and storage pneumatic systems.

The Pneumatic Level Switch is used with pneumatic pumping and storage systems. It consists of a rod connected to a float that opens/closes a valve positioned on the delivery line of compressed air towards the pneumatic pump (pneumatic submersible pump top inlet 2", pneumatic submersible pump top inlet 3", pneumatic submersible pump bottom inlet 2") or towards the active skimmer. Thereby, even without electric power in the site of the system, the pumping is stopped in case of filling of the storage tank. The Pneumatic Level Switch must be positioned between the source of compressed air and the pneumatic panel for pneumatic pumps. The Pneumatic Level Switch does not require electric power. 

  • Dimensions: total length = 45 cm, rod length = 35 cm (the rod length can be reduced to 15 cm) 

  • Minimum pressure: 3 bar 